Range technical data
- Minimum well classes
- 2, 2.5, 3, 4 and 6 in, according to subrange
- Motor power range
- 0.18–22 kW
- Maximum flow
- Up to 54 m³/h
- Maximum head
- Up to 450 m
- Discharge range
- 0.5–3 in, according to subrange
- Power supply
- 1~ 220–240 V or 3~ 380–415 V, 50 Hz; verify the model
Range bounds are a catalogue overview. Check flow and head together on the selected model curve; maximum values are not a guaranteed combined duty point.
Series catalogue ↗Series overview
Overview
The SA catalogue covers submersible water supply across several well sizes and includes model codes, motor options, performance tables and curves. Applications include water supply from wells or reservoirs, domestic, civil and industrial systems, and garden irrigation. The construction tables identify plastic impellers and AISI 304 stainless steel external casings, with other materials specified by pump size and component.
The overview states a maximum fluid temperature of 35 °C and maximum sand content of 0.25%. Check the actual water quality against these limits rather than inferring suitability from impeller material alone. Confirm the well opening, dynamic water level, required flow and total head, then select the exact model and electrical arrangement from its table.
Water supplyIrrigationIndustry
Features
- Multistage submersible well-pump hydraulics
- Plastic impellers identified in the construction tables
- Several well-size ranges with individual performance data
- Electrical variants specified by model
Applications
- Clean-water borehole supply
- Reservoir water supply
- Garden irrigation
Materials
AISI 304 stainless steel external pump and motor casings, plastic PC diffusers and plastic POM impellers in the listed constructions. Delivery casing materials vary with the selected size and configuration.
Operating conditions
Maximum fluid temperature 35 °C and maximum sand content 0.25%. Select the well-size range and electrical configuration from the applicable model page.
Before selecting
- Confirm the well opening, dynamic water level and required delivery pressure before choosing a range.
- Choose the model and stage count from the required flow and total head on the applicable curve.
- Check water temperature, sand content, power supply and control-box arrangement for the selected version.
Series questions
What are the SA impellers made from?
The construction tables specify POM plastic impellers and PC plastic diffusers, with stainless steel external casings. Check the material table for the selected size.
Can stage count be chosen from motor power alone?
Use the model performance curve and required flow and total head. The model code includes the number of impellers, so models in one flow family can have different heads.
Technical documents
SA PDF
19 pages · 419,4 KB
Choose the pump by the liquid, required flow and total head, electrical supply and installation conditions.