Range technical data
- Motor power range
- 0.55–2.2 kW
- Maximum flow
- Up to 48 m³/h
- Maximum head
- Up to 15.5 m
- Solids passage
- 38 or 50 mm, according to model
- Power supply
- 1~ 220–240 V or 3~ 380–415 V, 50 Hz
Range bounds are a catalogue overview. Check flow and head together on the selected model curve; maximum values are not a guaranteed combined duty point.
Series catalogue ↗Series overview
Overview
The FC light sewage pump is designed for submerged transfer in domestic, workshop and industrial systems. The catalogue describes an AISI 304 stainless steel pump assembly, a closed single-channel impeller and seals arranged around an oil-filled motor chamber. Its performance table separates the available electrical versions and operating points.
Although the source mentions some aggressive liquids, compatibility must be checked against the actual liquid and seal materials; combustible liquids are expressly excluded. Choose a model from its flow and head curve, then confirm that any entrained solids fit the passage stated for that model. This FC family remains a separate catalogue record from FC inox.
WastewaterIndustry
Features
- Closed single-channel impeller
- AISI 304 stainless steel pump construction
- Model-specific solids passage
- Single-phase and three-phase versions in the catalogue
Applications
- Domestic water drainage
- Workshop drainage
- Light industrial wastewater transfer
Materials
AISI 304 stainless steel pump construction and stainless steel motor shaft; oil-resistant nitrile rubber gaskets, silicon-carbide/alumina mechanical seal and an upper lip seal.
Operating conditions
Clean or slightly dirty water, with a maximum liquid temperature of 50 °C in continuous duty. Combustible liquids are prohibited. Maintain the pumping level at least 10 cm above the pump body; three-phase motor protection must be provided by the user.
Before selecting
- Match the required flow and head to the selected FC performance curve.
- Check suspended solids against the passage listed for the exact model, and confirm liquid compatibility with the seals and stainless steel.
- Confirm single-phase or three-phase supply, motor protection and the minimum operating water level.
Series questions
Can this FC pump handle solids?
The closed single-channel impeller can pass solids within the model-specific limit in the technical table. Confirm the solids before selecting a model.
Can FC pump combustible liquids?
No. The catalogue expressly prohibits combustible liquids. Check the actual liquid against the pump and seal materials for other duties.
Technical documents
FC PDF
2 pages · 700,6 KB
Choose the pump by the liquid, required flow and total head, electrical supply and installation conditions.