Range technical data
- Motor power range
- 1.5–110 kW
- Maximum flow
- Up to 2600 m³/h
- Maximum head
- Up to 65 m
- Discharge range
- DN50–DN300
- Power supply
- 1~ 220–240 V or 3~ 380–415 V, 50 Hz; availability depends on model
Range bounds are a catalogue overview. Check flow and head together on the selected model curve; maximum values are not a guaranteed combined duty point.
Series catalogue ↗Series overview
Overview
The WC series uses a semi-open vortex impeller with a cutter ring at the intake. Both cutting components are specified in high-chromium stainless steel, while tandem mechanical seals and an epoxy-sealed cable entry protect the motor assembly. The catalogue distinguishes two-pole and four-pole versions and gives separate performance curves and construction information.
WC is intended for submerged operation in wastewater and sewage containing material that the cutter can break down. Selection should follow the required duty point and the actual nature of the solids. Cutter construction does not replace checking that the liquid and installation conditions fall within the catalogue limits.
WastewaterTreatmentIndustry
Features
- Cutter impeller and ring ahead of the discharge path
- Semi-open vortex hydraulic design
- Tandem mechanical seals with silicon-carbide faces
- Epoxy-sealed cable entry
Applications
- Wastewater transfer
- Sewage pumping with fibrous material
- Drainage where cutting action is required
Materials
High-chromium stainless steel 420 cutter impeller and cutter ring; double mechanical seals with silicon-carbide faces.
Operating conditions
Wastewater and sewage at 0–40 °C. The IP68 motor is intended for continuous submerged operation. Built-in auto-cut thermal protection is specified for single-phase models.
Before selecting
- Identify the wastewater, fibrous material and cutting duty before choosing the pump.
- Match the required flow and total discharge head to the curve for the selected two-pole or four-pole model.
- Confirm power supply, motor protection and submerged operating conditions for the installation.
Series questions
What does the WC cutting assembly do?
The vortex semi-open impeller and cutter ring cut material in the wastewater before discharge. Check the actual waste stream when specifying the pump.
Is motor thermal protection included?
The catalogue specifies a built-in auto-cut thermal protector on single-phase models. Confirm the protection arrangement for the selected electrical version.
Technical documents
WC PDF
9 pages · 810,9 KB
Choose the pump by the liquid, required flow and total head, electrical supply and installation conditions.