FC-INOX / Stainless steel submersible wastewater pump

FC Inox Sewage Pump

FC Inox is the separate FC wastewater catalogue with a double-channel impeller and stainless steel wetted parts. Its stated applications span water exchange, drainage and filtration in agricultural and landscape settings. The model range and hydraulic data differ from the light FC catalogue and should be read independently.

Range technical data

Catalogue block: 2.2–7.5 kW
Flow up to 120 m³/h; head up to 24 m
Catalogue block: 11–15 kW
Flow up to 250 m³/h; head up to 30 m
Power supply
3~ 380–415 V
Solids passage
Stated range 6–52 mm

Range bounds are a catalogue overview. Check flow and head together on the selected model curve; maximum values are not a guaranteed combined duty point.

Series catalogue ↗

Series overview

Overview

FC Inox uses a double-channel impeller to move water containing suspended solids. The catalogue identifies AISI 304 stainless steel for the pump casing, motor casing, impeller and shaft, and lists model-specific performance data and a stated solids-passage range. It also specifies mechanical-seal materials and operating limits for submerged use.

This construction suits duties where stainless steel wetted components are relevant, but the actual liquid should still be checked against the stated materials and operating conditions. Use the FC Inox curve and model table to select flow and head. The common FC name does not make the light FC and FC Inox ranges interchangeable.

Water supplyWastewaterIrrigation

Features

  • Double-channel impeller
  • AISI 304 stainless steel wetted components
  • Published solids-passage data
  • Model-specific hydraulic curves

Applications

  • Water exchange in farming and fisheries
  • Landscape water drainage
  • Filtration-system water transfer

Materials

AISI 304 stainless steel pump casing, motor casing, double-channel impeller and shaft; SiC/SiC + Carbon/SiC mechanical seal and NBR O-ring.

Operating conditions

Clean water and sewage at 0–50 °C, with immersion depth up to 5 m. The brochure states a solids-passage range of 6–52 mm. Confirm suitability of the actual solids and liquid for the selected configuration.

Before selecting

  • Match the required flow and total head to the FC Inox model curve, including the separate 11–15 kW block where relevant.
  • Check liquid temperature, immersion depth and actual suspended solids against the stated conditions and passage range.
  • Confirm AISI 304 and seal compatibility, three-phase electrical supply and installation arrangement.

Series questions

Which parts are stainless steel?

The material table specifies AISI 304 for the pump casing, motor casing, impeller and shaft. The seal and O-ring use separate materials.

Is FC Inox suitable for both clean water and sewage?

Yes, both are listed applications. The selected pump must still meet the catalogue limits for temperature, immersion depth, solids and duty point.

Technical documents

FC-INOX PDF

3 pages · 659,7 KB

Choose the pump by the liquid, required flow and total head, electrical supply and installation conditions.

Related series

WC Cutter Sewage Pump
WC

WC Cutter Sewage Pump

WC combines a submersible sewage pump with a cutter impeller and ring. The cutting assembly reduces fibrous material before it enters the discharge path. The catalogue covers two-pole and four-pole constructions for wastewater and sewage duties where a standard drainage impeller may be more prone to obstruction.

View series
FC Light Sewage Pump
FC

FC Light Sewage Pump

FC is a light sewage range with a closed single-channel impeller. Its catalogue covers clean to slightly dirty water and lists the solids passage for each model. Stainless steel construction and single-phase or three-phase versions make it a distinct series from the larger FC stainless steel wastewater catalogue.

View series
KTZ-LH Drainage Pump
KTZ-LH

KTZ-LH Drainage Pump

The KTZ-LH catalogue combines two submersible drainage ranges with cast-iron construction and high-chrome-alloy impellers. KTZ has a semi-open impeller and ductile-iron wear plate; LH has a separately specified construction for deep-well pre-dewatering and high-head drainage. Both ranges list civil engineering, mining and treatment-plant applications.

View series
Lên đầu trang